NEXUS Network Ready Resolver
Interface For Stamping Press Control |
The concept of a resolver interface is nothing new to the
stamping press industry. The same cannot be said of AMCI's
NEXUS NX2A4_; arguably the most versatile resolver interface
available today. Engineered to provide absolute position and
velocity data directly to the network, the four resolver channels
can be configured three different ways: (4) single resolver
inputs, (2) dual resolver multiturn inputs, and (2) single
resolver inputs + (1) dual resolver multiturn input.
In addition to the above functionality, the NX2A4_ also
has a brake input that provides stopping time and brake applied
position to the network. This stamping press control
information can be used for brake wear monitoring thereby
ensuring operator safety.
With 13-bit resolution for single resolver applications
and 20-bit resolution for dual resolver multiturn applications,
the NX2A4_can be used in applications ranging from metal stamping
to high speed assembly overhead cranes. Whether your stamping
press control application calls for a single-turn resolver,
multi-turn resolver, or some combination of both, the NEXUS
Resolver Interface is the solution.
NEXUS
Network Ready Resolver Interface For Stamping Press
Control |
AMCI Model #
(please specify network when ordering) |
NX2A4_
Configured for Single
Resolver Transducers |
NX2A4_
Configured for Dual Resolver Multiturn Transducers |
| Network availability |
NX2A4C (ControlNet)
NX2A4D (DeviceNet)
NX2A4E (Ethernet IP)
NX2A4P (Profibus)
NX2A4T (Modbus TCP/IP) |
NX2A4C (ControlNet)
NX2A4D (DeviceNet)
NX2A4E (Ethernet IP)
NX2A4P (Profibus)
NX2A4T (Modbus TCP/IP) |
| Position sensor |
Resolver |
Resolver |
| Number of channels |
4 maximum |
2 maximum |
| Maximum full scale count |
8192 counts for single resolver transducers |
4096 counts / turn for dual resovler multiturn transducers |
| Position update time |
200us |
200us |
| DC supply requirements |
500 mA @24Vdc |
500 mA @24Vdc |
| Transducer compatibility |
|
HTT-20
/ HTT-400
/ HTT-425 |
| Cable requirements |
CTL-X
(X = length in feet) |
CML-X
(X = length in feet) |
Resolver Input
Connectors
(2 per unit) |
AMCI Part # = MS-8
Phoenix Contact Part # = MSTB2.5/8-ST-5.08
Two connectors are included with the unit
Each connector has three possible wiring configurations;
one Single Turn Resolver, Two Single Turn Resolvers,
or One Multiturn Resolver
One Single Turn Resolver (One CTL-X cable)

Two Single Turn Resolvers (Two CTL-X cables)
One Multiturn Resolver (One CML-X cable)
|
| Required hardware |
na |
na |
| Optional hardware |
na |
na |
| Additional stamping press controllers
& interfaces by AMCI: NEXUS
Position Controller
|